Bgs General Srl – Pompe per Vuoto – Vacuum Technology

Dry screw vacuum pumps BDRY

The new BDRY dry screw vacuum pumps are widely used in a variety of sectors worldwide.

COMPARISON BETWEEN SCREW VACUUM PUMPS

Dry Vacuum Pump
(Base 400 m3/hr)
NEW BDRY Vacuum Pump
(BDRY400)
Competitor Vacuum Pump
(430 m3/hr)
Ultimate Pressure
(torr)/50Hz
0.0075 torr 0.03 torr
Motor Power 11kw 11kw
Exhaust Gas Temperature Below 120℃ Below 150℃
Moisture and liquid
processing capability
Smooth emission structure (1)
Superior liquid flowing ability
Not Smooth emission structure
The structure is not feasible to drain of liquid that is inappropriate for liquid processing.
 Condensation Vapor
processing capability
Installed Gas ballast (2) nozzle
Prevent condensation of vapor by the gas ballast
No Gas ballast nozzle installed
Condensation occurs inside the pump.
Condensed vapor or solvent are deposited inside
pump and could cause overload trip.
 Corrosive vapor
processing capability
PTFE or PFA Coating application
Prevent condensation of corrosive vapor by the gas ballast.
By step-by-step compression, maintains low pump-inside temperature and protects coating.
PTFE or PFA Coating applications
Cumulated condensation of corrosive substances
may cause frequent seal damage.
 Lubrication(Oil)
Gear box side
Gear Oil Coolant Jacket (3)
Maintains low oil temperature
Preventing oil leak and change of oil performance.
No Gear Oil Coolant Jacket
The oil temperature inside gear box shall be risen.
It may makes oil leak and change of oil performance.
Cooling gas
(casing)
No need
No extra cooling gas required.
Maintains low temperature by step-by-step compression.
Hydrodynamic spiral jacket design ensures
excellent heat exchange efficiency.
Needed
In hazardous areas
Heat exchanger for cooling of circulation gas is required.
Additional equipment and maintenance cost increases.
In non-hazardous areas
If the cooling gas filter clogged, the pumps is seizured.

Note:

1

Smooth emission Structure:
Screw Vacuum Pump have an inherent disadvantage when it comes to draining and flushing. The exhaust port is small and is not at the lowest point in the Vacuum Pump so liquid will not drain out of the Vacuum Pump. But, the exhaust port of BDRY Vacuum Pump is big and is at the lowest point in the Vacuum Pump so liquid will drain out of the Vacuum Pump smoothly.

2

Gas ballast:
The basic principle of ballast is that Non-condensable gas (N2 or air) is admitted into a pump during the gas compression stages. This increases the percentage of non-condensable gas such that the partial pressure of the vapor being pumped is below its saturated vapor pressure.

3

Gear Oil Coolant Jacket:
The lubricant oil in the gear box is cooled by a cooling water jacket.

COMPARISON OF DIFFERENT VACUUM PUMP TECHNOLOGY

Screw Dry Pump

Liquid Ring

Rotary Vane Pump

BDRY SCREW VACUUM PUMPS MODELS

50Hz (60Hz)
Nominal pumping speed
Ultimate pressure
Nominal motor rating
Nominal motor speed
Noise level
Weight
(without motor )
 
m3/h
Tarr
Kw – 3 ~
rpm
dB(A)
Kg
BDRY 150
110 (130)
7,5 X 10-3 4,0
2900 (3500)
79 (85)
190
BDRY 300
250 (300)
7,5 X 10-3
 7,5
2900 (3500)
79 (85)
290
BDRY 400
330 (400)
7,5 X 10-311,0 2900 (3500) 79 (85) 370
BDRY 800
660 (800)
7,5 X 10-3 15,0 2900 (3500) 79 (85) 580
BDRY 1500
1.250 (1.500)
 7,5 X 10-3 30,0 2900 (3500) 79 (85) 900

MAIN APPLICATIONS

Distillation

Application:

Monoglycerides, Vegetable oils, Fatty acids, Vitamin A, Vitamin E, Esters, Chlorinated, Hydrocarbons, Silicon oils, Polyglycols, Macro-paraffins, Phthalates, Sebacates, Fragrances, Pharmaceuticals,Essences, Pyrethrum, Insecticides.

Market:

Distillation Plant, Chemical Processors, Vegetable Oil Producers, Pharmaceutical Companies, Reclaimers.

Vacuum System:

Inlet Condenser, Catch Pot (Knock-Out Pot), Inlet Isolation Valve, Outlet Condenser, Stainless Steel Piping.

Typical Distillation Condition:

Operating Temperature 120 ~ 280 °C – Operating Pressure 0.1 ~ 20 mbar

50Hz (60Hz)
Portata Nominale
Vuoto Finale
Potenza Motore
Giri Motore
Rumorosità
Capacità Olio
Peso
m3/h
mbar (a)
Kw – 3 ~
Kw – 1 ~
giri/min.
dB(A)
Litri
Kg
3 PBO
3 (3,6)
10
0,11 (0,11)
0,11
2750 (3300)
57
0,1
7
3 PBOM
3 (3,6)
2
0,11 (0,11)
0,11
2750 (3300)
57
0,1
7

Evaporation

Application:

Pharmaceutical intermediates, Heat sensitive pharmaceuticals, Food, Water desalination, Liquid effluent, Black liquor concentration in paper and pulp industry, Concentration of sugar cane and sugar beet juices, Ammonium nitrate, Sodium hydroxide, Phosphoric acid, Recovery of plating and photographic solutions, Concentration of radioactive waste.

Market:

Mainstream chemical manufacturers, Pharmaceutical manufacturers, Specialist chemicals manufacturers General chemical laboratories, Food producers, Sugar and salt industries, Pup and paper industries, Large plating and photographic workshops, Nuclear waste reprocessing facilities, Waste disposal companies.

Typical Evaporation Condition:

Operating Pressure 0.1 ~ 50 mbar

50Hz (60Hz)
Portata Nominale
Vuoto Finale
Potenza Motore
Giri Motore
Rumorosità
Capacità Olio
Peso
m3/h
mbar (a)
Kw – 3 ~
Kw – 1 ~
giri/min.
dB(A)
Litri
Kg
6 PBO
6 (7,4)
10
0,18 (0,18)
0,37
2750 (3300)
65
0,2
13
6 PBOM
6 (7,4)
0,5
0,18 (0,18)
0,37
2750 (3300)
65
0,2
13

Reactions

Application:

Reaction of fine chemicals – Pharmaceutical, Intermediates, Chemical reactions, Synthesis of chemical and petrochemical compounds, Polymerisation, Pyrolysis of fragrances, Cracking of hydrocarbons and chemical compounds Organo-metallic reaction and processes.

Market:

Pharmaceutical manufacturers, Fine chemical industries, General chemical and petrochemical industry, Fragrance manufacturers, Paint and glue manufacturers, Resin and plastics industry.

Vacuum System:

Inlet Condenser , Catch Pot(Knock-Out Pot), Inlet Filter, Inlet Isolation Valve, Outlet Condenser, Gas Ballast, Stainless Steel Piping.

Typical Reactions Condition:

Operating Pressure 0.01 ~ 50 mbar

50Hz (60Hz)
Portata Nominale
Vuoto Finale
Potenza Motore
Giri Motore
Rumorosità
Capacità Olio
Peso
m3/h
mbar (a)
Kw – 3 ~
Kw – 1 ~
giri/min.
dB(A)
Litri
Kg
3 PBO
3 (3,6)
10
0,11 (0,11)
0,11
2750 (3300)
57
0,1
7
3 PBOM
3 (3,6)
2
0,11 (0,11)
0,11
2750 (3300)
57
0,1
7

Drying

Application:

Pharmaceutical products and their intermediates, Food products including soups and beverages, Fine chemicals, Dyes and pigments, Filter cakes, Plastics (polymer granules), Building materials.

Market:

Mainstream chemical products, Pharmaceutical manufacturers, Fine chemical producers, Food/drinks industry, General chemical laboratories, Building materials producers.

Vacuum System:

Inlet Condenser , Catch Pot(Knock-Out Pot), Inlet Isolation Valve, Outlet Condenser, Stainless Steel Piping.

Typical Drying Condition:

Operating Temperature ambient ~ 300 °C – Operating Pressure 0.001 ~ 50 mbar

50Hz (60Hz)
Portata Nominale
Vuoto Finale
Potenza Motore
Giri Motore
Rumorosità
Capacità Olio
Peso
m3/h
mbar (a)
Kw – 3 ~
Kw – 1 ~
giri/min.
dB(A)
Litri
Kg
6 PBO
6 (7,4)
10
0,18 (0,18)
0,37
2750 (3300)
65
0,2
13
6 PBOM
6 (7,4)
0,5
0,18 (0,18)
0,37
2750 (3300)
65
0,2
13

Degassing

Application:

Transformer and switchgear oils, hydrocarbon oil, Turbine lubrication and seal oils, Brake fluids,, Phosphate esters and other hydraulic oils, Synthetic fluids, Silicone oils, Fluorocarbon oils, Resins, Paints and polymers, Glues and adhesives,Pastes, Water for medical, food and boiler uses.

Market:

Electrical equipment manufacturers, Electricity generation, transmission and distribution boards Oil refining and supply companies, Hydraulic control and equipment manufacturers, Automotive and allied industries, Aircraft and aviation industry, Chemical and allied industries.

Vacuum System:

Inlet Condenser , Catch Pot(Knock-Out Pot), Inlet Isolation Valve, Outlet Condenser, Stainless Steel Piping.

Typical Degassing Condition:

Operating Pressure 0.01 ~ 50 mbar

50Hz (60Hz)
Portata Nominale
Vuoto Finale
Potenza Motore
Giri Motore
Rumorosità
Capacità Olio
Peso
m3/h
mbar (a)
Kw – 3 ~
Kw – 1 ~
giri/min.
dB(A)
Litri
Kg
3 PBO
3 (3,6)
10
0,11 (0,11)
0,11
2750 (3300)
57
0,1
7
3 PBOM
3 (3,6)
2
0,11 (0,11)
0,11
2750 (3300)
57
0,1
7

Refrigeration

Application:

Rapid evaporative cooling of: market garden products, water and high water content liquids, cooked, baked or high temperature processed foods, distributed dairy products, picked fruits.

Market:

Dairies, Food processors, Breweries, Fruit and vegetable importers/exporters, Market gardens, Agricultural institutions.

Vacuum System:

Inlet Condenser , Catch Pot(Knock-Out Pot), Inlet Filter, Inlet Isolation Valve, Outlet Condenser, Gas Ballast, Stainless Steel Piping.

50Hz (60Hz)
Portata Nominale
Vuoto Finale
Potenza Motore
Giri Motore
Rumorosità
Capacità Olio
Peso
m3/h
mbar (a)
Kw – 3 ~
Kw – 1 ~
giri/min.
dB(A)
Litri
Kg
6 PBO
6 (7,4)
10
0,18 (0,18)
0,37
2750 (3300)
65
0,2
13
6 PBOM
6 (7,4)
0,5
0,18 (0,18)
0,37
2750 (3300)
65
0,2
13

Pervaporation (Membrane)

Application:

Ethanol , Isopropanol, Higher alcohols, Ketones, Aldehydes, Esters. Pervaporation is primarily used for removing water from a range of aqueous organic liquids.

Market:

Pervaporation Plant Manufacturers, Pharmaceuticals, Biotechnology, Chemicals, Solvent Recovery.

Vacuum System:

nlet Condenser , Catch Pot(Knock-Out Pot),Inlet Isolation Valve, Outlet Condenser,Stainless Steel Piping.

Typical Pervaporation Condition:

Operating Temperature 70 ~ 90 °C – Operating Pressure 1 ~ 50 mbar

50Hz (60Hz)
Portata Nominale
Vuoto Finale
Potenza Motore
Giri Motore
Rumorosità
Capacità Olio
Peso
m3/h
mbar (a)
Kw – 3 ~
Kw – 1 ~
giri/min.
dB(A)
Litri
Kg
3 PBO
3 (3,6)
10
0,11 (0,11)
0,11
2750 (3300)
57
0,1
7
3 PBOM
3 (3,6)
2
0,11 (0,11)
0,11
2750 (3300)
57
0,1
7

Filtration

Application:

Specific chemical (Apple juice, Barium carbonate, Barium sulphate, Calcium carbonate, Portland Cement, Corn syrup,Kaolin, Lithium carbonate, Magnesium oxide, Nickel carbonate,H2PO4, Silica gel, Silver chloride, Sodium bicarbonate, Sodium nitrate, Corn starch, Titanium dioxide, Zinc carbonate) Proteins, Fermentation residues.

Market:

Mainstream chemical producers, Food/drink industry, Pharmaceutical manufacturers, Fine chemical producers, General chemical laboratories/universities.

Vacuum System:

Inlet Condenser , Catch Pot(Knock-Out Pot),Inlet Isolation Valve, Outlet Condenser,Stainless Steel Piping.

Typical Filtration Condition:

Operating Pressure 1 ~ 100 mbar

50Hz (60Hz)
Portata Nominale
Vuoto Finale
Potenza Motore
Giri Motore
Rumorosità
Capacità Olio
Peso
m3/h
mbar (a)
Kw – 3 ~
Kw – 1 ~
giri/min.
dB(A)
Litri
Kg
6 PBO
6 (7,4)
10
0,18 (0,18)
0,37
2750 (3300)
65
0,2
13
6 PBOM
6 (7,4)
0,5
0,18 (0,18)
0,37
2750 (3300)
65
0,2
13

Freeze Drying

Application:

Pharmaceuticals and biologicals (vaccines, antibiotics,blood fraction, etc.) Biological specimens (animals, birds, insects, museum displays, etc.) Fine chemicals, Food and beverages (coffee, tea, vegetables, etc.) Metals and metal oxides (ultra fine powders)

Market:

Pharmaceutical companies, Hospitals, laboratories, universities, museums, Fine chemical producers, Food manufacturers, Veterinary institutions.

Vacuum System:

Inlet Isolation Valve, Outlet Condenser,Stainless Steel Piping.

Typical Freeze Drying Condition:

Operating Pressure 0,025 ~ 1,0 mbar

50Hz (60Hz)
Portata Nominale
Vuoto Finale
Potenza Motore
Giri Motore
Rumorosità
Capacità Olio
Peso
m3/h
mbar (a)
Kw – 3 ~
Kw – 1 ~
giri/min.
dB(A)
Litri
Kg
3 PBO
3 (3,6)
10
0,11 (0,11)
0,11
2750 (3300)
57
0,1
7
3 PBOM
3 (3,6)
2
0,11 (0,11)
0,11
2750 (3300)
57
0,1
7

Vacuum Pressure Impregnation (VPI)

Application:

Electrical components, such as transformers,capacitors, chokes, resistors, power cables, monitors Proofing and treatment of bulk textiles, Proofing of wood, fiber boards, concrete/fiber panels, Sealing of castings, especially aluminum castings, Lubrication of sintered bearing surfaces, Fumigation/sterilization of vegetables, fruits, feathers and fibrous fillings.

Market:

Electrical equipment and components manufacturers, Wood importers, saw mills, wood product processors Food importers, Foundries and OEM, Textile and home furnishing industry.

Vacuum System:

Inlet Condenser , Catch Pot(Knock-Out Pot),Inlet Isolation Valve, Outlet Condenser, Stainless Steel Piping.

Typical VPI Condition:

Operating Pressure 0,001 ~ 50 mbar

50Hz (60Hz)
Portata Nominale
Vuoto Finale
Potenza Motore
Giri Motore
Rumorosità
Capacità Olio
Peso
m3/h
mbar (a)
Kw – 3 ~
Kw – 1 ~
giri/min.
dB(A)
Litri
Kg
6 PBO
6 (7,4)
10
0,18 (0,18)
0,37
2750 (3300)
65
0,2
13
6 PBOM
6 (7,4)
0,5
0,18 (0,18)
0,37
2750 (3300)
65
0,2
13

Vapor Recovery Unit (VRU)

Application:

Gasoline, Kerosene, Jet Fuels, Crude Oil, Diesel Fuels, Distillate Fuels, Ethanol, Methanol, Butanol, Benzene, Toluene, Xylene, Butane, Propane, Pentane, Pentene, Hexane, Isobutane, Carbon Tetrachloride, Naphtha, Chlorobenzene, Chloroethane, Cyclohexane, Dichloroethane, Dichloromethane, Trichloroethane, Trichloroethylene, Ethyl Tert-Butyl Ether, Methyl Tert-Butyl Ether, Ethyl Acetate, Methylene Chloride, Perchloroethylene, Methyl Ethyl Ketone, Ethybenzene.

Market:

Refineries, Petrochemical factories, Oil terminals, Marine terminals, Storage tank vents, Process vents, Truck loading racks, Railcar loading facilities, VRU manufacturers.

Vacuum System:

Inlet Isolation Valve, Liquid Injection, Absorber Column.

Typical VRU Condition:

Operating Temperature 80 °C or less – Operating Pressure 33 mbar ~ Atm.

50Hz (60Hz)
Portata Nominale
Vuoto Finale
Potenza Motore
Giri Motore
Rumorosità
Capacità Olio
Peso
m3/h
mbar (a)
Kw – 3 ~
Kw – 1 ~
giri/min.
dB(A)
Litri
Kg
3 PBO
3 (3,6)
10
0,11 (0,11)
0,11
2750 (3300)
57
0,1
7
3 PBOM
3 (3,6)
2
0,11 (0,11)
0,11
2750 (3300)
57
0,1
7

Steel Degassing

Application:

Vacuum degassing (VD), Vacuum oxygen decarburization (VOD), Vacuum degassing oxygen blowing (VDOB), Vacuum carbon decarburization (VCD), Ruhrstahl-Heraeus (RH), Vacuum induction melting (VIM), Vacuum induction degassing (VID).

Market:

Electric steelmaking, Oxygen steelmaking, Ironmaking and steelmaking.

Vacuum System:

Inlet Filter, Vacuum Booster, Cooler, Inlet Isolation Valve, Purge Valve, Stainless Steel Piping.

Typical Steel Degassing Condition:

Operating Temperature 40-70 °C – Operating Pressure 0,67 mbar ~ Atm.

50Hz (60Hz)
Portata Nominale
Vuoto Finale
Potenza Motore
Giri Motore
Rumorosità
Capacità Olio
Peso
m3/h
mbar (a)
Kw – 3 ~
Kw – 1 ~
giri/min.
dB(A)
Litri
Kg
6 PBO
6 (7,4)
10
0,18 (0,18)
0,37
2750 (3300)
65
0,2
13
6 PBOM
6 (7,4)
0,5
0,18 (0,18)
0,37
2750 (3300)
65
0,2
13

Vacuum Furnace

Application:

Homogenisation, Stress relieving, Normalising, Hardening, Tempering, Sintering, Annealing, Brazing, Carburizing, Melting, Out-gassing.

Market:

Vacuum Furnace manufacturers, Vacuum Furnace Plants, Laboratories, Research institutes.

Vacuum System:

Inlet Filter, Vacuum Booster, Cooler, Inlet Isolation Valve, Purge Valve, Stainless Steel Piping.

Typical Vacuum Furnace Condition:

Operating Pressure 0,001 mbar ~ Atm.

50Hz (60Hz)
Portata Nominale
Vuoto Finale
Potenza Motore
Giri Motore
Rumorosità
Capacità Olio
Peso
m3/h
mbar (a)
Kw – 3 ~
Kw – 1 ~
giri/min.
dB(A)
Litri
Kg
3 PBO
3 (3,6)
10
0,11 (0,11)
0,11
2750 (3300)
57
0,1
7
3 PBOM
3 (3,6)
2
0,11 (0,11)
0,11
2750 (3300)
57
0,1
7